hoistway.co.uk./service Lifts/specfications 500 - 1500kg


500kg's           << Back to Service Lifts homepage



Model


Capacity

car
Width   Depth   Height

Entrance
Width   Height
Service
height

Shaft
Width   Depth

Pit Depth


Headroom
500B
500EU
500kg
500kg
1045
1035
1235#
1235#
2000
2000
1010
1305
2000
2000
Floor Level
1650
1950
1500
1500
150*
150*
2800
2800

750kg's           << Back to Service Lifts homepage



Model


Capacity

car
Width   Depth   Height

Entrance
Width   Height
Service
height

Shaft
Width   Depth

Pit Depth


Headroom
750B
750EU
750s
750kg
750kg
750kg
1045
1035
1045
1235#
1235#
1735#
2000
2000
2000
1010
1305
1010
2000
2000
2000
Floor Level
1650
1950
1650
1500
1500
2000
150*
150*
150
2800
2800
2800

1000kg's           << Back to Service Lifts homepage



Model


Capacity

car
Width   Depth   Height

Entrance
Width   Height
Service
height

Shaft
Width   Depth

Pit Depth


Headroom
1000B
1000EU
1000S
1000ED
1000DS
1000kg
1000kg
1000kg
1000kg
1000kg
1045
1305
1045
1445
1445
1235#
1235#
1735#
1435#
1735#
2000
2000
2000
2000
2000
1010
1305
1010
1410
1410
2000
2000
2000
2000
2000
Floor Level
1650
1950
1650
2050
2050
1500
1500
2000
1700
2000
150*
150*
150*
150*
150*
2800
2800
2800
2800
2800

1500kg's           << Back to Service Lifts homepage



Model


Capacity

car
Width   Depth   Height

Entrance
Width   Height
Service
height

Shaft
Width   Depth

Pit Depth


Headroom
1500D
1500DS
1500kg
1500kg
1445
1445
1435#
1735#
2000
2000
1410
1410
2000
2000
Floor Level
2050
2050
1700
2000
150*
150*
3000
3000

* PIT OR RAMP: The Goodsmaster normally serves at floor level and would require a pit in the lowest floor. If you are unable to provide a pit, the Goodsmaster can be installed to serve at 150mm above the lowest floor and a ramp will need to be provided by your builder.

# CAR DEPTH: With a through car entrance arrangement, the inside car depth reduces by 25mm nominal.



Important Notes:- Motor Housing and Pit/Ramp MOTOR HOUSING: It will be necessary to provide access for servicing via lockable double hinged doors for the full depth of the lift shaft.

Consideration must be given to protect any accessible space beneath the bottom of the lift shaft. We would be pleased to provide further information if required.

Safe Maintenance Access
Please be aware that current Health & Safety Regulations, i.e. Construction Design & Management and The Provision & Use of Work Equipment specify; Access to all parts of machinery requiring maintenance must be planned to be both safe and accessible. The Goodsmaster you are planning to install requires regular maintenance. Therefore careful planning will be required to ensure safe access into the motor compartment is provided. The Goodsmaster normally requires 2 maintenance access points. The location of these points of access will depend on the landing door positions needed.For further advice please contact us on T: 01935 823369.


Service Lifts



Choice of entrance arrangements
Up to two way entry on every floor is possible, giving you maximum access to the lift